+86-760-89736111 / 89966715 / 89966716 

Your present position is:HomeProductsGas water valve gas water linked valve
  • Details Description Goods Description
  • B size

    Features:

    1. Net weight:1.19kgs
    2. To be used on 13L-16L gas water heater.
    3. Gas path leakage inspection: under the gas pressure 15Pa, the tolerance to allow the gas leakage flow≦0.015L/h for the first valve; for the other valves, ≦0.3L/h. 
    4. Endurability of water valve inspection: under water pressure1.5Mpa up to 1minute, there is no damage, no water leakage, out of shape and more
    5. Water relief valve: when water pressure up to 1Mpa, the valve starts to work. 
    6. Under water pressure 0.1Mpa,the water flow is as below
    Model (L)  10
    Min. water flow (L/min) 4.17-5
    Max. water flow (L/min) ≧10.5
    7. Min. start-up water pressure: ≦0.025Mpa; Min. start-up water flow: 130-150L/h; Max. start-up water pressure: >0.05Mpa. 
    8. Unidentified size tolerance is according to GB/T 1804-m; geometrical tolerance is according to GB/T1184-k.
    9. The force to close the solenoid valve: 70±10%gf.

gas water linked valve